European Journal of Prosthodontics and Restorative Dentistry

Effect of Chairside CAD/CAM Restoration Type on Marginal Fit Accuracy: A Comparison of Crown, Inlay and Onlay Restorations

Effect of Chairside CAD/CAM Restoration Type on Marginal Fit Accuracy: A Comparison of Crown, Inlay and Onlay Restorations

Abstract

Chairside CAD/CAM is a convenient approach for fabricating dental restorations. However, the effect of CAD/CAM restoration type on marginal fit accuracy has not been fully investigated. This study evaluated of the marginal fit accuracy of 3 chairside CAD/ CAM restoration types (crown, inlay and onlay) using CEREC Bluecam (BC) and CEREC Omnicam (OC) scanners. Three artificial maxillary first molars received crown, inlay and onlay preparations. A total of 10 CAD/CAM ceramic restorations were produced for each tooth by each intraoral scanner. The marginal gap was measured along the preparation margin. For the BC, all the restorations had similar marginal gaps (crowns = 113.9 µm; inlays = 120.9 µm; onlays = 132.5 µm) (p = 0.20), while for the OC, the crowns (72.2 µm) and
the inlays (74.9 µm) exhibited better marginal fit than the onlays (96.4 µm) (p = 0.003). For every restoration type, the OC provided a superior outcome compared with the BC. Therefore, the restoration type influenced the marginal gap, where the crowns tended to have the least marginal gap while the onlays had the greatest marginal gap. The newer scanner (OC) of the same manufacturer was more accurate than the older scanner (BC).

Keywords
Inlay
Crown
Fit
Marginal Gap
Onlay

Authors

Tyson C. Merrill, Thomas Mackey, Raymond Luc, Dominique Lung, Aneela Naseem, Jaafar Abduo

Articles from this issue

Title / DOI Access Page Start Page End View
Transferring Occlusal Anatomy from Worn Temporary Crowns to Zirconium Oxide Crowns free access 67 75 view
A 3D Finite Element Analysis of Bone Tissue in 3-Unit Implant-Supported Prostheses: Effect of Splinting Factor and Implant Length and Diameter free access 76 83 view
Influence of Flat Occlusal Splint on Stresses Induced on Implants for Different Fixed Prosthetic Systems free access 84 92 view
The Effect of Demineralization and Remineralization Cycles on the Bond Strength of Resin Composite to Enamel free access 93 101 view
A 3-D Finite Element Analysis of a Single Implant Retained Overdenture Reinforced with Short Versus Long Frameworks free access 103 111 view
The Influence of Connection on the Microleakage Development of ImplantSupported Fixed Bridges free access 112 118 view
Effect of Chairside CAD/CAM Restoration Type on Marginal Fit Accuracy: A Comparison of Crown, Inlay and Onlay Restorations free access 119 127 view
  • free access Free Access
  • no access No Access
  • full access Full Access

Subscriptions